Change AutoConnect from int to bool.
[tinc] / doc / tinc.conf.5.in
index 632c849..072bf07 100644 (file)
@@ -1,4 +1,4 @@
-.Dd 2013-01-14
+.Dd 2014-01-29
 .Dt TINC.CONF 5
 .\" Manual page created by:
 .\" Ivo Timmermans
@@ -114,15 +114,13 @@ If
 .Qq any
 is selected, then depending on the operating system both IPv4 and IPv6 or just
 IPv6 listening sockets will be created.
-.It Va AutoConnect Li = Ar count Po 0 Pc Bq experimental
-If set to a non-zero value,
+.It Va AutoConnect Li = yes | no Po no Pc Bq experimental
+If set to yes,
 .Nm
-will try to only have
-.Ar count
-meta connections to other nodes,
-by automatically making or breaking connections to known nodes.
-Higher values increase redundancy but also increase meta data overhead.
-When using this option, a good value is 3.
+will automatically set up meta connections to other nodes,
+without requiring
+.Va ConnectTo
+variables.
 .It Va BindToAddress Li = Ar address Op Ar port
 This is the same as
 .Va ListenAddress ,
@@ -169,7 +167,9 @@ The names should be known to this tinc daemon
 line).
 .Pp
 If you don't specify a host with
-.Va ConnectTo ,
+.Va ConnectTo
+and don't enable
+.Va AutoConnect ,
 .Nm tinc
 won't try to connect to other daemons at all,
 and will instead just listen for incoming connections.
@@ -586,6 +586,12 @@ Setting this options also implicitly sets IndirectData.
 .Pp
 Since version 1.0.10, tinc will automatically detect whether communication via
 UDP is possible or not.
+.It Va Weight Li = Ar weight
+If this variable is set, it overrides the weight given to connections made with
+another host. A higher
+.Ar weight
+means a lower priority is given to this connection when broadcasting or
+forwarding packets.
 .El
 .Sh SCRIPTS
 Apart from reading the server and host configuration files,